PRODUCTS. Measurements
General information
Projects
Regions
News
Media
Company responses
Vacancy
Contacts
Site map
General information
Mining enterprises design
Booklets
Photos
Deposit Mathematical model
Advantage
Photos
Booklets
Методика построения математической модели месторождения
Optimum open PIT design
Advantage
Photos
Booklets
Operational planning
Advantage
Photos
Booklets
The automated control systems
Advantage
Photos
Booklets
Ore sorted and ore separation
Advantage
Photos
Booklets
Ore concentration of noble and rare metals
Photos
Booklets
>
PRODUCTS
Measurements
The AC-4 equipment
The AC-104
The automated control systems
Software
ПО РСК
ПО АСУ АТ+КР
САПР ТП ГП
The process equipment
Tab. No. 1
Поставки коллективного концентрата оксидов редкоземельных металлов (РЗМ).


The AC-4

The amplitude coding AC -4 is intended to be used as spectrometric and radiometric systems with moderate energy resolution and increased loads.

The AC-4 was made on the bases of the ISA standard , and can be found in both the PC standard configuration, and more compact industrial electronics format MicroPC format.

Specifications AK-4

1. The number of independent channel coding

4

2. The number of level changes

8

3. Time change

< 2 mks

4. Capacity buffer memory in the channel

256 • 8 bytes

5. Maximum load on the entrance to lapses 10% and the length of the input pulses 2

50 • 103 с-1

6. Analog input pulses :

polarity

the maximum amplitude

length Front

input impedance

input connectors

 

positive

5 ± 1V

< 0,2 mks

~ 2 kOm

LEMO

7. Digital Inputs and Outputs

levels

Inputs

Outputs

 

TTL

4

4

8. Interface Card

124х106х24 mm

9. Connector Standard

ISA

10. Temperature range operating

-20оС ¸ +70оС

11. Power Consumption

< 1 Vt

 

For CA-4 developed driver and libraries allow developers to create sub-program for DOS and Windows XP.

Gas- electroluminescent detection Cluster (GEDC) is 2,5 times better resolution than proportionate gas detectors (Mn Ka -5,9keV).

The GEDC registration area surface approximately 4 times greater than that of silicon detectors for recording X-rays in the energy range.

All these allows for the use of detectors that include express analysis of polymetallic ores.

GEDC specifications

1. Ambient registration keV

2-30

2. The registration of radiation energy 15 keV,%

70

3. Entrance window diameter mm

20

4. Maximum speed accounts, c-1

3*104

5. Energy permission to the Mn Ka - 5.9 keV,%

8

6. Radiation detector resource

Unlimited